NUCLEAR MEDICINE IMAGING SOLUTIONS · SHANGHAI, CHINA

HERMIA molecular imaging
software platform

NDMed (NuSight Digital Medical) distributes the HERMIA molecular imaging software platform from Hermes Medical Solutions in China: a vendor-neutral suite for review, reconstruction, quantitative analysis, specialty applications and dosimetry modules in nuclear medicine imaging.

Vendor-neutral · All-in-one suite · Quantitative reconstruction & dosimetry modules · Clinical specialties

Review & reconstruction

REVIEW & RECONSTRUCTION

Quantification

QUANTIFICATION

Dosimetry modules

DOSIMETRY MODULES

Clinical specialties

CLINICAL SPECIALTIES

SOFTWARE PLATFORM · CHINA MARKET DISTRIBUTION

PLATFORM OVERVIEW

HERMIA | The all-in-one molecular imaging suite

HERMIA is a vendor-neutral molecular imaging platform from Hermes Medical Solutions that combines review, reconstruction, quantification, specialty applications and dosimetry modules in one suite for clinical research and quantitative analysis in nuclear medicine imaging. NDMed is its China-market distributor.

Platform and module descriptions are compiled from Hermes Medical Solutions official documentation; no self-drawn product structure or feature schematics are used. Module names, configuration, regulatory status and availability follow the manufacturer documentation.

MODULE PORTFOLIO

Software modules configurable by specialty and workflow

Specialty applications and processing tools can be selected as needed; OLINDA/EXM, 4DM and Cedars are third-party products integrated via HERMIA.

HERMIA PLATFORM

HERMIA Platform

Review, reconstruction, processing and reporting for PET / SPECT / CT / MR; specialties selectable as modules.

VENDOR-NEUTRAL

HERMIA DOSIMETRY

HERMIA Dosimetry

Voxel and organ dosimetry plus SIRT planning and verification for personalised radionuclide therapy.

VOXEL · ORGAN · SIRT

OLINDA / EXM

OLINDA / EXM

MIRD-based organ and whole-body dose; integrated in HERMIA Organ Dosimetry or available standalone.

VIA HERMIA

CORRIDOR4DM

Invia Corridor4DM (4DM)

Quantitative cardiac SPECT analysis, integrated as a third-party module in the HERMIA cardiology line.

VIA HERMIA · CARDIOLOGY

CEDARS-SINAI

Cedars-Sinai Cardiac Suite

The Cedars quantitative cardiac imaging suite, available through the HERMIA cardiology line.

VIA HERMIA · CARDIOLOGY

SPECIALTY APPLICATIONS

Clinical Specialties & Processing

Oncology, neurology, cardiology and pneumology applications, plus SPECT reconstruction, SUV SPECT and NM processing tools.

ONCOLOGY · NEURO · CARDIAC

Software platform capabilities

CLINICAL RESEARCH · QUANTIFICATION · DOSIMETRY

Clinical research

Quantitative workflows for clinical research in nuclear medicine imaging, harmonised across cameras and sites.

Quantitative analysis

Quantitative PET / SPECT reconstruction, uptake quantification, time–activity curves and kinetic modelling.

Centiloid scale

Centiloid is a published HERMIA Neurology feature providing a standardised 0–100 scale for amyloid PET.

HERMIA Dosimetry

Hybrid / Voxel / Monte Carlo and OLINDA/EXM (MIRD) modules in HERMIA Dosimetry, plus SIRT planning and verification.

VENDOR SOFTWARE FIGURES

HERMIA interface and feature figures

All figures below are taken from the official Hermes Medical Solutions product pages. Platform and module descriptions are compiled solely from manufacturer documentation; no self-drawn product structure or feature schematics are used.

HERMES OFFICIAL FIGURES

Organ Dosimetry product page figure from hermesmedical.com: whole-body planar images and CT organ contours

Organ Dosimetry | Organ dose workflow

Interface from the official Organ Dosimetry product page: serial whole-body planar images, organ contours and CT slices, illustrating how the organ dose workflow is presented.

SPECT Reconstruction product page figure from hermesmedical.com: quantitative SPECT images and SUV results

SPECT Reconstruction | Quantitative reconstruction and SUV

Figure from the official SPECT Reconstruction product page: planar and tomographic quantitative SPECT, fused imaging and SUV quantification results, illustrating the reconstruction features.

Quantitative neuroimaging display figure from the Hermes Centiloid Scale product page

Neurology | Quantitative neuroimaging display

Quantitative neuroimaging display figure from the official Centiloid Scale product page, illustrating how quantitative brain imaging results are presented in specialty applications.

Images from the Organ Dosimetry, SPECT Reconstruction and Centiloid Scale pages of hermesmedical.com. Copyright Hermes Medical Solutions; reproduced for software feature illustration only. Module names, configuration and isotope support follow the manufacturer documentation.

SOFTWARE PLATFORM MODULES

RECONSTRUCTION & DOSIMETRY METHODS

Quantitative Reconstruction & Dosimetry: Software Platform Modules

The methods and workflows below are compiled from the official Hermes Medical Solutions instructions for use, product pages and white papers, and correspond to HERMIA reconstruction and dosimetry modules. Module names, algorithms, isotope support and configuration follow the manufacturer documentation.

METHOD · HYBRID

Hybrid Dosimetry (organ dose workflow)

Serial WB / SPECT-CT registration → ROI / VOI → count-to-activity conversion → TAC fitting and integration → OLINDA/EXM (MIRD) dose. Corresponds to the HERMIA Organ Dosimetry workflow.

TAC · TIAC · MIRD · OLINDA

METHOD · VOXEL

Voxel Dosimetry

Monte Carlo photon transport through the patient CT yields voxel dose maps, DVHs and dose tables, with deformable registration and semi-automatic segmentation. Hermes lists ²²⁵Ac, ²¹¹At, ²¹²Pb, ¹⁷⁷Lu, ⁹⁰Y and ⁸⁹Zr among supported isotopes.

DOSE MAP · DVH · MC TRANSPORT

METHOD · MONTE CARLO

Monte Carlo dose calculation

Monte Carlo is used twice: photon transport for voxel dose, and collimator–detector response modelling in SPECT reconstruction (high-energy isotopes such as ¹²³I, ¹³¹I, ⁹⁰Y; specific isotope–collimator combinations only).

PHOTON TRANSPORT · COLLIMATOR RESPONSE

METHOD · SPECT

Quantitative SPECT Reconstruction

Iterative reconstruction compensates attenuation, collimator blur, scatter and noise; CT attenuation maps, scatter windows and SUV-SPECT® calibration convert counts to activity / SUV.

SUV-SPECT® · ATTENUATION · SCATTER

METHOD · ALPHA

²²⁵Ac and alpha-emitter reconstruction

HERMIA Voxel Dosimetry lists ²²⁵Ac, ²¹¹At and ²¹²Pb. Energy windows, collimators, calibration and reconstruction parameters for alpha emitters require verification per camera and protocol.

²²⁵Ac · ²¹¹At · ²¹²Pb

CHAIN · FROM IMAGE TO DOSE

From image to absorbed dose

  1. Quantitative SPECT / PET reconstruction and activity calibration
  2. Time–activity curve fitting, cumulated activity / residence time
  3. Organ dose (MIRD / OLINDA) or voxel dose (Monte Carlo)
  4. Dose map, DVH and dose results table

As software platform modules

HERMIA provides quantitative SPECT reconstruction, Hybrid / Voxel Dosimetry, OLINDA/EXM and SIRT planning modules. Module names, algorithms, isotope support and configuration follow the Hermes documentation.

Sources: Hybrid Viewer Dosimetry IFU, Voxel Dosimetry, SPECT Reconstruction white paper. Configuration, regulatory status and isotope–collimator combinations follow the manufacturer documentation.

PRODUCT FIGURES

Software feature figures

Figures from the Hermes Medical Solutions product pages, illustrating how software features are presented.

HERMIA Voxel Dosimetry screenshot: 3D dose map, organ regions, time-activity curves and DVH

Voxel Dosimetry | Dose map & DVH

3D absorbed-dose distribution, semi-automatic organ regions, time–activity curves and dose volume histograms in HERMIA Voxel Dosimetry. Isotope support and configuration follow the manufacturer documentation.

Quantitative SPECT and PET lesion SUVpeak comparison figure from the Hermes SPECT Reconstruction page

Quantitative SPECT | SUV calibration

Hermes-published comparison of lesion SUVpeak in ⁹⁹ᵐTc-HDP SPECT and ¹⁸F-NaF PET, illustrating the output of quantitative SPECT reconstruction and activity calibration.

Fused whole-body imaging with lesion uptake from the Hermes Theranostics page

Theranostics | Whole-body quantification

Figure from the Hermes Theranostics page: lesion uptake on fused imaging, the input to downstream quantitative analysis and dose calculation.

Images from the Voxel Dosimetry, SPECT Reconstruction and Theranostics pages of hermesmedical.com. Copyright Hermes Medical Solutions; reproduced here for software feature illustration only. Module names, configuration and isotope support follow the manufacturer documentation.

ABOUT US

NDMed · NuSight Digital Medical

China-market distributor of the HERMIA molecular imaging software platform

NDMed distributes the HERMIA molecular imaging software platform from Hermes Medical Solutions in China, providing platform capability information, module configuration discussions and access to manufacturer documentation. Based in Shanghai, China.

Chinese legal name

上海睿观数科医药科技有限公司

English legal name

Shanghai NuSight Digital Medical Technology Ltd.

Brand / short name

NDMed · 睿观数科 · NuSight Digital Medical

Product enquiries & collaboration

For HERMIA platform capabilities, module configuration, product documentation or a demonstration, please contact us through our WeChat official account.

OFFICIAL WECHAT ACCOUNT

WeChat Official Account: 睿观数科 (NDMed)

Use the Business Cooperation menu item or leave a message. Further technical content is available on the account.